• Our lab, one of the few to perform this type of tests, has developed a unique expertise in impact testing.
  • Lamifil’s test environment features high speed monitoring.
  • Impact resulting from up to 4m drop height can be simulated.
  • A sample with mounted compression clamps is prepared, the free length between the compression clamps is approximately 3m;
  • The conductor is suspended vertically with a pretension of 200 kg to straighten the conductor;
  • A dynamic load is applied by dropping 666 kg weight from an elevation of 4m;
  • The measurement sample frequency of the load cell is 2500 measurements/s;
  • A full report is prepared including test object data, test description, set-up, procedure, load vs. time curve and conclusions.